Write short notes on short circuit rating of LT cables

Zillionsbuyer by Zillionsbuyer
July 4, 2020
in Electrical
0
selection of conductors.

selection of conductors.

Short circuit rating of LT cables :

LT CAble
LT CAble

(i)The short circuit for aluminum cables is different for copper cables. Copper can withstand higher temperature than aluminum.

(ii)With the recent increase in kVA capacity of the power distribution system, the cables are expected to carry short circuit currents of higher magnitudes

(iii) If it is required that the cables should be predicted from higher temperature during short circuit, it is essential that the fuses should be designed to minimize the fault duration

(iv)HRC fuses are best suited for low tension power supply circuits, because of the following reasons

1. They limit the magnitude of short circuit current.

2. They minimize the fault duration time

(v)Under short circuit conditions the current flowing the cable is many times the full load value of current. The heat produced in the conductor is proportional to the square of the current.

(vi)The duration of short circuit is very small. The temperature attained under short circuit conditions is greater than the maximum permissible temperature for continuous rating

(vii)The short circuit is not defected by the condition of installation of the cable but it depends upon the maximum temperature attained by the cable under short circuit condition

(viii)The safe value of limiting temperature is usually taken as 120°C. for maximum continuos operating conductor temperature of 800 C and a permissible temperature rise of  500 C during short circuit.

Tags: LT Cables
Previous Post

What is overload rating of cables & also explain

Next Post

Write short note on De rating factor for LT. Cable

Next Post
Write short note on De rating factor for LT. Cable

Write short note on De rating factor for LT. Cable

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

No Result
View All Result

Recent Posts

  • Everything one needs to know regarding metal cutting tools
  • How to make the paint on your home last long? 
  • Why changing over to changeover switches is convenient? 
  • Coaxial cable application and uses
  • Your complete guide to buy a demolition hammer

Recent Comments

  • mta travel information on What is meant by MEMS
  • memorial day sales on What is meant by MEMS
  • Yaoi on What is meant by MEMS
  • gaming on What is meant by MEMS
  • no deposit bonus on What is meant by MEMS

Browse by Category

  • Civil
  • Electrical
  • Industry
  • Manufacturing
  • Mechanical
  • Uncategorized

Recent News

Everything one needs to know regarding metal cutting tools

Everything one needs to know regarding metal cutting tools

July 12, 2021
How to make the paint on your home last long?

How to make the paint on your home last long? 

July 12, 2021
No Result
View All Result

© 2021

Welcome Back!

Login to your account below

Forgotten Password?

Create New Account!

Fill the forms bellow to register

All fields are required. Log In

Retrieve your password

Please enter your username or email address to reset your password.

Log In