{"id":821,"date":"2020-07-01T16:26:45","date_gmt":"2020-07-01T16:26:45","guid":{"rendered":"https:\/\/www.zillionsbuyer.com\/blog\/?p=821"},"modified":"2020-08-03T09:55:45","modified_gmt":"2020-08-03T09:55:45","slug":"what-is-fan-performance-evaluation-and-efficient-system-operation","status":"publish","type":"post","link":"https:\/\/www.zillionsbuyer.com\/blog\/what-is-fan-performance-evaluation-and-efficient-system-operation\/","title":{"rendered":"What is Fan Performance Evaluation And Efficient System Operation"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"638\" height=\"359\" src=\"https:\/\/www.zillionsbuyer.com\/blog\/wp-content\/uploads\/2020\/07\/Fan-Performance-Evaluation-And-Efficient-System-Operation.jpg\" alt=\"\" class=\"wp-image-822\" srcset=\"https:\/\/www.zillionsbuyer.com\/blog\/wp-content\/uploads\/2020\/07\/Fan-Performance-Evaluation-And-Efficient-System-Operation.jpg 638w, https:\/\/www.zillionsbuyer.com\/blog\/wp-content\/uploads\/2020\/07\/Fan-Performance-Evaluation-And-Efficient-System-Operation-300x169.jpg 300w\" sizes=\"auto, (max-width: 638px) 100vw, 638px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The factors involved in fan\nperformance evaluation and efficient system operation are as follows:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>(1)System characteristics :<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The system resistance is the sum of\nstatic pressure losses in the system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It varies with the square of the\nvolume of air flowing through the system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Long narrow ducts with many bends and\ntwists will require more energy to pull the air through them.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thus, the system resistance increases\nsubstantially as the volume of air flowing through the system increases.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2) Fan characteristics :<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The fan curve is a performance curve\nfor the particular fan under a specific set of conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Typically a curve will be developed\nfor a given set of conditions usually including : fan volume, system static\npressure, fan speed, and brake horsepower required to drive the fan under the\nstated conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The intersection of the system curve\nand the static pressure curve defines the operating point. When the system\nresistance changes, the operating point also changes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Once the operating point is fixed,\nthe power required could be found by following a vertical line that passes\nthrough the operating point to an intersection with the power (BHP) curve.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A horizontal line drawn through the\nintersection with the power curve will lead to the required power on the right\nvertical axis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>(3) System characteristics and fan\ncurves :<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In any fan system, the resistance to\nair flow (pressure) increases when the flow of air is increased.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The pressure required by a system\nover a range of flows can be determined and a &#8220;system performance cur can\nbe developed<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This system curve can then be plotted\non the fan curve to show the fan&#8217;s actual operating point at &#8221;A&#8221; where the\ntwo curves intersect.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This operating point is at air flow\nDelivered against pressure P A fan operates along a performance given by the\nmanufacturer for a particular fan speed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The fan performance chart shows\nperformance curves for a series of fan speeds.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">At fan speed N, the fan will operate\nalong the N performance curve as shown in Fig given below.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>(4) Fan laws:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The fans operate under a predictable\nset of laws concerning speed, power and pressure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A change in speed (RPM) of any fan\nwill predictably change the pressure rise and power necessary to operate it at\nthe new RPM.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The factors involved in fan performance evaluation and efficient system operation are as follows: (1)System characteristics : The system resistance is the sum of static pressure losses in the system. It varies with the square of the volume of air flowing through the system. Long narrow ducts with many bends and twists will require more [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":822,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[44],"tags":[],"class_list":["post-821","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical-engineering"],"_links":{"self":[{"href":"https:\/\/www.zillionsbuyer.com\/blog\/wp-json\/wp\/v2\/posts\/821","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zillionsbuyer.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.zillionsbuyer.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.zillionsbuyer.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.zillionsbuyer.com\/blog\/wp-json\/wp\/v2\/comments?post=821"}],"version-history":[{"count":2,"href":"https:\/\/www.zillionsbuyer.com\/blog\/wp-json\/wp\/v2\/posts\/821\/revisions"}],"predecessor-version":[{"id":2298,"href":"https:\/\/www.zillionsbuyer.com\/blog\/wp-json\/wp\/v2\/posts\/821\/revisions\/2298"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zillionsbuyer.com\/blog\/wp-json\/wp\/v2\/media\/822"}],"wp:attachment":[{"href":"https:\/\/www.zillionsbuyer.com\/blog\/wp-json\/wp\/v2\/media?parent=821"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.zillionsbuyer.com\/blog\/wp-json\/wp\/v2\/categories?post=821"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.zillionsbuyer.com\/blog\/wp-json\/wp\/v2\/tags?post=821"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}